指南卡 117
译本:机器初稿
气体——有毒——易燃(极度危险)
Gases - Toxic - Flammable (Extreme Hazard)
中国境内请拨:火警 119 · 急救 120 · 报警 110;化学品泄漏或中毒另可拨国家化学事故应急咨询专线 0532-83889090(24 小时)。英文原文沿用 ERG 原版(美国为 911)。
潜在危害(火灾与爆炸)
这些物质极度易燃。
These materials are extremely flammable.可能与空气形成爆炸性混合物。
May form explosive mixtures with air.可能被热、火花或火焰点燃。
May be ignited by heat, sparks or flames.液化气蒸气初期比空气重,沿地面扩散。
Vapors from liquefied gas are initially heavier than air and spread along ground.蒸气可能扩散至点火源并回火。
Vapors may travel to source of ignition and flash back.标有 (P) 的物质在受热或涉及火灾时可能发生爆炸性聚合。
Those substances designated with a (P) may polymerize explosively when heated or involved in a fire.径流可能造成火灾或爆炸危险。
Runoff may create fire or explosion hazard.受火烤的气瓶可能通过泄压装置排放并释放有毒易燃气体。
Cylinders exposed to fire may vent and release toxic and flammable gas through pressure relief devices.容器受热可能爆炸。
Containers may explode when heated.破裂的气瓶可能飞出。
Ruptured cylinders may rocket.健康危害
有毒;极度危险。
TOXIC; Extremely Hazardous.吸入或经皮肤吸收可致命。
May be fatal if inhaled or absorbed through skin.初始气味可能刺鼻或恶臭,并可能使嗅觉迟钝。
Initial odor may be irritating or foul and may deaden your sense of smell.接触气体或液化气体可能造成灼伤、重伤和(或)冻伤。
Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite.火灾会产生刺激性、腐蚀性和(或)毒性气体。
Fire will produce irritating, corrosive and/or toxic gases.灭火用水或稀释水的径流可能造成环境污染。
Runoff from fire control or dilution water may cause environmental contamination.公众安全
拨打 119(火警)/120(急救)/110(报警)。然后拨打运输单据上的应急响应电话号码;如无运输单据或无人接听,请拨国家化学事故应急咨询专线 0532-83889090(24 小时),或查阅封底内页所列的相应电话号码。
CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.无关人员远离。
Keep unauthorized personnel away.位于上风向、地势较高处和(或)上游。
Stay upwind, uphill and/or upstream.许多气体比空气重,会沿地面扩散并积聚在低洼或受限区域(下水道、地下室、罐体等)。
Many gases are heavier than air and will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.).进入密闭空间前先通风,但仅在受过训练并配备装备时进行。
Ventilate closed spaces before entering, but only if properly trained and equipped.立即预防措施
Immediate precautionary measure向四周隔离泄漏区至少 100 米(330 英尺)。
Isolate spill or leak area for at least 100 meters (330 feet) in all directions.泄漏
Spill见表 1——初始隔离和防护距离。
See Table 1 - Initial Isolation and Protective Action Distances.火灾
Fire如罐车、铁路罐车或公路罐车涉及火灾,向四周隔离 1600 米(1 英里);同时考虑向四周 1600 米(1 英里)实施初始疏散。
If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions.消防措施
除非能够止漏,否则切勿扑灭正在泄漏的气体火灾。
DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED.小面积火灾
Small Fire干粉、二氧化碳、喷雾水或普通泡沫。
Dry chemical, CO2, water spray or regular foam.大面积火灾
Large Fire喷雾水、雾状水或普通泡沫。
Water spray, fog or regular foam.在安全可行的情况下,将未受损的容器移离火场周边区域。
If it can be done safely, move undamaged containers away from the area around the fire.破损气瓶只能由专业人员处理。
Damaged cylinders should be handled only by specialists.罐车火灾
Fire Involving Tanks从最远距离灭火,或使用无人操作的大口径水枪或遥控水炮。
Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.用大量水冷却容器,直至火灾扑灭后很长时间。
Cool containers with flooding quantities of water until well after fire is out.切勿将水直接射向泄漏源或安全装置;可能发生结冰。
Do not direct water at source of leak or safety devices; icing may occur.如泄压安全装置发出声响增大或罐体变色,立即撤离。
Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.始终远离直接接触火焰的罐体。
ALWAYS stay away from tanks in direct contact with flames.防护服
佩戴正压自给式呼吸器(SCBA)。
Wear positive pressure self-contained breathing apparatus (SCBA).在无火灾风险时,穿着制造商专门推荐的化学防护服。
Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.消防员结构防护服可提供热防护,但化学防护能力有限。
Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.泄漏处置
消除周边区域的一切点火源(禁止吸烟、明火、火花或火焰)。
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.处理该产品所用的一切设备必须接地。
All equipment used when handling the product must be grounded.切勿触碰或踩踏泄漏物。
Do not touch or walk through spilled material.在无风险的情况下堵漏。
Stop leak if you can do it without risk.用喷雾水降低蒸气浓度或改变蒸气云漂移方向。避免径流接触泄漏物。
Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.切勿将水直接射向泄漏物或泄漏源。
Do not direct water at spill or source of leak.如有可能,翻转泄漏容器,使气体逸出而非液体流出。
If possible, turn leaking containers so that gas escapes rather than liquid.防止泄漏物进入水体、下水道、地下室或受限空间。
Prevent entry into waterways, sewers, basements or confined areas.隔离该区域,直至气体扩散完毕。
Isolate area until gas has dispersed.可考虑点燃泄漏物以消除有毒气体隐患。
Consider igniting spill or leak to eliminate toxic gas concerns.急救
特殊急救:
Specific First Aid:如接触液化气体,结霜部位只能由医务人员尝试解冻。
In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts.如发生烧伤,立即用冷水尽可能长时间冷却受伤皮肤。衣物粘在皮肤上时切勿撕脱。
In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin.在加拿大,本产品可能要求制定应急响应援助计划(ERAP)。请查阅运输单据和(或)「ERAP」章节。
In Canada, an Emergency Response Assistance Plan (ERAP) may be required for this product. Please consult the shipping paper and/or the "ERAP" section.适用物质(4 个物质)
- 氰化氢,稳定的,含水少于3% UN 1051
- 硫化氢 UN 1053
- 甲硫醇 UN 1064
- 无水硒化氢 UN 2202